Choose a Scan Method

The SureSmile system supports  a variety of scan technologies for the convenience of you and your patients. Although the availability of each source of scan data depends on the type of model you are ordering, the scan technologies available are described below.

Scanners approved by Dentsply Sirona for use with SureSmile

Handheld intraoral optical scanners:

 

Limitations: All CBCT  scanners must be certified by SureSmile before scans can be accepted. Optical scanners used for intraoral bracket scans must be certified. Intraoral non-bracket scans and scans of plaster models may be done with any optical scanner. Follow the instructions on the following forms to have your scanner certified.

Technology

Description

Use for

Optical scan of a plaster model, using either:
  • orascanner
  • desktop or handheld scanner
  • diagnostic model
  • final model

Optical scan of a patient, using a SureSmile-certified handheld scanner:
  • CEREC Omnicam (Dentsply Sirona)
  • orascanner 2 (Dentsply Sirona)
  • iTero orthodontic imaging system (Align Technology, Inc.)
  • iOC intraoral scanner (Align Technology, Inc.)
  • TRIOS 3, TRIOS Color, TRIOS Standard (3Shape, Inc.)
  • 3M True Definition Scanner (3M)
  • diagnostic model
  • Unbonded therapeutic model
  • Standard therapeutic model
  • Premium therapeutic model (used in combination with CBCT scan)
  • Updated therapeutic model (may be used in combination with original therapeutic model CBCT scan)
  • final model

CBCT scan of a plaster model at the clinic or an imaging center, using a SureSmile-certified CBCT scanner:
  • i-CAT - Classic, Next Generation, or FLX
  • CareStream - CS 8100 3D, CS 9300 or K9500
  • Planmeca - ProMax 3D, 3D Mid, or 3D Max
  • diagnostic model
  • final model

CBCT scan of a patient at the clinic or an imaging center, using a SureSmile-certified CBCT scanner:
  • i-CAT - Classic, Next Generation, or FLX
  • CareStream - CS 8100 3D, CS 9300 or K9500
  • Planmeca - ProMax 3D, 3D Mid, or 3D Max
  • diagnostic model
  • unbonded therapeutic model
  • standard therapeutic model
  • premium therapeutic model (used in combination with optical scan)
  • final model

Ordering Models from Scans

For detailed instructions for ordering models from CBCT scans, orascans, or optical scans (.STL files) please go to Scanning Protocols and download the protocol for the scanner you are using. You will find detailed step-by-step procedures for ordering each kind of model.